rmn_biospec

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
rmn_biospec [2009/06/09 13:24]
miquel
rmn_biospec [2020/07/09 12:30] (current)
miquel
Line 1: Line 1:
 ====== Espectròmetre Biospec 7T ====== ====== Espectròmetre Biospec 7T ======
  
-===== Incidències =====+<WRAP important> 
 +La informació relativa a la configuració del BioSpec ha estat traslladada a la [[:administracio_sermn:biospec | part privada del wiki.]] 
 +</WRAP>
  
-==== 2009 ====+{{:administracio_sermn:bruker:biospec:img_3316_001.jpg?300 | Imant 70/30USR del Biospec}} L'espectròmetre Bruker Biospec 70/30USR es va adquirir a mitjans de 2005 i la seva instal·lació, després de diversos endarreriments, va tenir lloc el juliol de 2007.
  
-^ Data  ^  Responsable(s)  ^  Incidència  ^  Observacions +Disposa d'un imant 70/30USR ultra-apantallat i refrigerat ---sense dewar de nitrogen líquid--- amb un camp magnètic de 7 Tesles i una freqüència de ressonància del nucli d'hidrogen de 300 MHz. Els 300 mm de diàmetre intern de l'imant permeten acomodar animals de fins la mida d'un conill petitAlhora, els accessoris de de mini microimatge de que disposa permeten l'estudi de mostres de mida petitaper exemplegrans de blat de moro arròs.
-| 2009-06-09 | Silvia, Miquel  | Preparatius inicials pel manteniment de l'imant  | **2009-06-09** Trucada d'en Ruben García (tel. +34-609-158-445, Bruker Española) per comentar que fàbrica ja ha fixat una primera data pel manteniment de l'imant, i que ens enviaran la notificació per correu electrònic. El cost de la intervenció serà de 25 k€, i caldrà encarregar uns 400-500 litres d'heli líquidEn cas de //quench// el consum d'heli líquid pujaria fins a 1200 litresi caldrà assegurar-se que Carburos Metálicos els tingui en stock i que ens els puguin subministrar urgentment en cas de necessitat. +
-| 2009-06-08 | Silvia, Miquel  | Accessori micro-MRI i actualització a Paravision 5  | **2009-06-08** Arribada del tècnic de Bruker (Bernard) del cilindre de gradients (GAD SYSTEM BFG 113/60/S6 CLB=1,5M; Part. No./Var: O10357/0) enviat a fàbrica per reparació. +
-| 2009-02-25 | Silvia, Miquel  | 7.2 cm ID transmiter volume coil (ref. T10720) damaged. El sistema neumàtic de fixació del ressonador té una fuita i no manté la sonda a la seva posició.  | **2009-02-25** S.I.: 09T30005 per l'enviament del ressonador a fàbrica. **2009-03-18** Sortida cap a fàbrica. **2009-05-13:** Arribada del ressonador reparat.   | +
-| 2008-08-28 | Silvia, Miquel  | Accessori micro-MRI i sondes addicionals  | **2009-01-13** El paquet va arribar a Barcelona el divendres 2008-12-19, però no ens el van lliurar, després d'insistir-hi, fins el 2009-01-13. **2009-01-13 a 15** Instal·lació i !!>posta a punt parcial!! del nou equipament, ja que un component clau, el cilindre de gradients (GAD SYSTEM BFG 113/60/S6 CLB=1,5M; Part. No./Var: O10357/0)arriba amb un connector equivocat i s'ha de tornar a fàbrica.  **2009-01-14:** Enviament del cilindre de gradients a fàbrica (referències: PT100608 TH281488) |+
  
-==== 2008 ====+===== Configuració, incidències, i altres =====
  
-^ Data  ^  Responsable(s)  ^  Incidència  ^  Observacions +Per informació sobre la configuració de l'espectròmetreestació de treball programari, i les incidències relacionades amb aquest instrument consulteu la pàgina corresponent a la [[:administracio_sermn:biospec intrawiki.]]
-| 2008-08-28 | Silvia, Miquel  | Phase-array, resonator, ...  | **2008-08-28** El Phase Array (PA), el ressonador addicional, i altres materials estan a Barcelona des de mitjans d'agostperò l'agència de transports, per un motiu o altre, encara no ens els han dut. **2008-09-08: ** Finalment arriba el PA. **2008-10-13 a 17** Instal·lació posta a punt del PA.  | +
-| 2008-06-27 | Miquel      | Faraday Cage door knob replaced  | The Faraday Cage door knob has been replaced. This timesince FC warranty still holds valid, we got a replacement door knob from MR Schutztechnik. It is a model by [[http://http://www.serme.it | Meroni Serrature]]. Fortunately, they have a local representative   [[http://www.cerraval.es/ | Cerraval (Cerrajerías Valencianas)]]. **Product reference: Use code N17, Finishing ref. US26D.** +
-| 2007-12-21 | Silvia, Miquel   | 7.2 cm ID transmiter volume coil (ref. T10720) damaged. El sistema neumàtic de fixació del ressonador té una fuita no manté la sonda a la seva posició.  | **2007-12-21** L'enviament de la sonda a fàbrica està previst per just abans de Setmana Santa. S.I.: 07T30016. Finalment, atès que és el ressonador més emprat, vàrem decidir esperar a l'arribada d'un 2n ressonador idèntic amb el Phase-array per enviar aquest. **2008-11-07** nova SI núm 08T30013 per l'enviament del ressonador a fàbrica. **2008-11-11** Sortida cap a fàbrica.  **2008-11-27:** El ressonador reparat surt de fàbrica. **2008-12-03:** Arriba el ressonador.   | +
-| 2007-12-17 | Silvia, Miquel   | Shim unit does not turn on correctly when gradient unit is switched on  | **2008-02-25: PROBLEM SOLVED: GPSCU exchanged by Bernard Wilt**. **2008-02-11** Bernard Wilt has sent an email saying that the GPSCU unit would be sent to us today to be replaced next week. **2008-01-23** Bernard Wilt and Francis Antoine from Bruker BioSpin France visited us and checked the problem. Bernard decided to replace the GPSCU unit. **2007-12-21** PENDENT DE RESPOSTA DE FÀBRICA. Quite often, the "ready/reset" and the "on/power" button on the shims amplifier don´t lit up when starting the gradients, however the lights of the shim channels get lit. When this happens it is impossible to have good shims, and all spectroscopy experiments are really bad. Most times we fix the problem re-starting the gradient unit, but sometimes we need to turn off/on the GCU 4-5 times before the shim amplifier starts. !!>SI-07T30017!! +
-===== Manuals ===== +
- +
-  * {{:manuals_tecnics:refrig_gradients_biospec:neslab_merlin-25_tech_manual.pdf|Refrigerador NESLAB Merlin 25}} +
- +
-===== Configuració de la xarxa externa ===== +
- +
-La xarxa externa dels ordinadors dels espectròmetres s'ha de configurar amb una IP estàtica per evitar que una caiguda de la xarxa bloquegi el funcionament del ParaVision (i potser del Topspin, però no estic segur). Per més informació consulta la pàgina sobre [[:informatica:xarxa:espectrometres | Configuració de la xarxa externa dels espectròmetres.]] +
- +
-===== Addició d'un 2n disc dur intern ===== +
- +
-Per tal d'augmentar l'espai de disc disponible per dades, a principis d'abril de 2009 es va instal·lar un segon disc dur intern. El model de disc dur pel que vàrem optar, després de consultar diferents pàgines web, i més concretament seguint el consell a [[http://www.hardwaresecrets.com/article/627 | 500 GB Hard Disk Drive Round-Up]] (Hardware Secrets, núm. 627) va ser el [[http://www.wdc.com/en/products/products.asp?DriveID=489 Western Digital RE3 (WD5002ABYS).]] +
- +
-El disc dur és detectat (''ata2''), reconegut (''Model: WDC WD5002ABYS-0'') i configurat (''dev 0 configured for UDMA/133'') pel Red Hat Enterprise 3 (Red Hat Linux 3.2.3-54, GNU/Linux 2.4.21-40.EL), +
- +
-<code> +
-$ more /var/log/dmesg +
-Linux version 2.4.21-40.EL (bhcompile@hs20-bc1-7.build.redhat.com) (gcc version +
-3.2.3 20030502 (Red Hat Linux 3.2.3-54)) #1 Thu Feb 2 22:32:00 EST 2006 +
-... +
-SCSI subsystem driver Revision: 1.00 +
-libata version 1.20 loaded. +
-PCI(00:1f.2): version 1.2 +
-PCI: Found IRQ 5 for device 00:1f.2 +
-PCI: Setting latency timer of device 00:1f.2 to 64 +
-PCI(00:1f.2): AHCI 0001.0100 32 slots 4 ports 3 Gbps 0xf impl SATA mode +
-PCI(00:1f.2): flags: 64bit ncq pm led clo pio slum part +
-ata1: SATA max UDMA/133 cmd 0xF8843500 ctl 0x0 bmdma 0x0 irq 5 +
-ata2: SATA max UDMA/133 cmd 0xF8843580 ctl 0x0 bmdma 0x0 irq 5 +
-ata3: SATA max UDMA/133 cmd 0xF8843600 ctl 0x0 bmdma 0x0 irq 5 +
-ata4: SATA max UDMA/133 cmd 0xF8843680 ctl 0x0 bmdma 0x0 irq 5 +
-ata1: dev 0 cfg 49:2f00 82:3069 83:7c01 84:4023 85:3069 86:3401 87:4023 88:203f +
-ata1: dev 0 ATA-7, max UDMA/100, 312581808 sectors: LBA48 +
-ata1: dev 0 configured for UDMA/100 +
-ata2: dev 0 cfg 49:2f00 82:746b 83:7f61 84:4163 85:7469 86:be41 87:4163 88:207f +
-ata2: dev 0 ATA-8, max UDMA/133, 976773168 sectors: LBA48 +
-ata2: dev 0 configured for UDMA/133 +
-... +
-scsi3 : ahci +
-  ... +
-  Vendor: ATA       Model: WDC WD5002ABYS-0  Rev: 02.0 +
-  Type:   Direct-Access                      ANSI SCSI revision: 05 +
-Attached scsi disk sdb at scsi1, channel 0, id 0, lun 0 +
-SCSI device sdb: 976773168 512-byte hdwr sectors (500108 MB) +
- sdb: unknown partition table +
-... +
-</code> +
- +
-Fent servir els programes ''sfdisk'' i ''fdisk'' es poden consultar diferents dades tècniques del disc, +
- +
-<code> +
-# sfdisk -g /dev/sdb +
-/dev/sdb: 60801 cylinders, 255 heads, 63 sectors/track +
- +
-# fdisk -l /dev/sdb +
- +
-Disk /dev/sdb: 500.1 GB, 500107862016 bytes +
-255 heads, 63 sectors/track, 60801 cylinders +
-Units = cylinders of 16065 * 512 = 8225280 bytes +
- +
-Disk /dev/sdb doesn't contain a valid partition table +
-</code> +
- +
-i aparentment tot indica que el disc no conté cap partició, +
- +
-<code> +
-# fdisk /dev/sdb +
-Device contains neither a valid DOS partition table, nor Sun, SGI or OSF disklabel +
-Building a new DOS disklabel. Changes will remain in memory only, +
-until you decide to write them. After that, of course, the previous +
-content won't be recoverable. +
-... +
-Command (m for help): m +
-... +
- +
-Command (m for help): v +
-976768064 unallocated sectors +
- +
-Command (m for help): u +
-Changing display/entry units to sectors +
- +
-Command (m for help): p +
- +
-Disk /dev/sdb: 500.1 GB, 500107862016 bytes +
-255 heads, 63 sectors/track, 60801 cylinders, total 976773168 sectors +
-Units = sectors of 1 * 512 = 512 bytes +
- +
-   Device Boot    Start       End    Blocks   Id  System +
- +
- +
-</code>+
  
rmn_biospec.1244546640.txt.gz · Last modified: 2009/06/09 13:24 by miquel